Product Description

1. application:3.2-50T  double girder crane

2. sensitivity:±5%(F.S)

3. error:±5%

4. over load capacity of load cell:150%

5. work environment:-307090%RH

6. mains voltage: ~220V/~380v±10%  50HZ

7. relay contact capacity:220v 15A    380v 10A

8. load cell protect class: IP65

9. electric control box protection class:IP42

10. set up warning point

1) warning forecast---9-0% of the rated load(yellow glint, buzzer warning sound warning intermittently. but don’t cut off power supply )

2) warning delay----105% of the rated load(delay 1~2 seconds red light, buzzer sound warning continuously. then cut off power supply)

3) warning immediately----130% of the rated load(red light, buzzer sound warning continuously .then cut off power supply at once)



Hits: 【Print】